- Walk-through of the complete unboxing and setup process for the Prisma Dual.
- Adjustable wrench
- Gloves
- Utility knife
- Power drill (a screwdriver also works)
Remove the top panel of the crate
- The Prisma Dual arrives in a wooden crate secured with metal L brackets.
- Remove the top panel by unscrewing the L brackets along the top edge.
- Repeat for all L brackets securing the top panel.
- Lift the top panel off.
- Remove the screws from the L brackets securing the front panel.
- Remove the front panel.
- Repeat the same process for each remaining side panel until the machine is fully exposed.
Release the machine from the crate base
- Locate the metal brackets securing the machine to the base of the crate.
- Remove the three screws from each bracket to release the machine from the crate base.
- At the base of the Prisma Dual, locate the adjustable leveling feet.
- Using an adjustable wrench, rotate each leveling foot clockwise to raise it off the ground.
- Confirm the machine can roll freely.
Remove protective cover
- Remove the protective cover from the Prisma Dual.
- Locate the 2x4 beam under the Prisma Dual and place it vertically against the pallet.
- Take one of the removed crate panels and position it against the 2x4 to create a ramp.
- Bend the L brackets downward and secure the ramp using screws to ensure it is stable.
- With multiple people assisting, carefully roll the machine down the ramp.
- Open the side cabinets.
- Inside are five accessory boxes, each labeled with a number.
Install the platen (Accessory Box #3)
- Open accessory box number three.
- Remove the platen.
- Place the platen into position until it seats fully.
- Push the locking lever to the side to secure the platen.
- Shake the platen lightly to confirm it is secured properly.
- Compare it to the other platen to confirm both are positioned the same.
Connect the air compressor (Accessory Box #1)
- Open accessory box number one to access the air compressor.
- Take the air tube and connect it to the compressor output.
- Pull back the locking ring, insert the tube until it clicks, then release the ring to lock.
- Connect the other end of the air tube to the machine’s air port.
- Push the tube in fully to ensure a secure connection.
- Open accessory box number two to access the foot pedal assembly and cables.
- Slide the strain relief collar against the pedal assembly.
- Rotate the strain relief collar clockwise to secure the cable.
- Connect the other end of the pedal cable to the corresponding port on the machine.
- Tighten the locking ring clockwise.
- Plug the main power cable into the Prisma Dual.
- Locate the waste bin and position it underneath the machine as shown.
- Remove the protective plastic from the laser guides.
- Open accessory box number four to access the laser guide pads.
- Open accessory box number five to access the Teflon cover (optional cover for platens).
Plug in and power on the air compressor
- Plug the Prisma Dual and the air compressor into a power outlet.
- On the compressor, rotate the red knob toward the airline to open airflow.
- Pull the red knob upward to power the compressor on.
- Verify the pressure gauge begins to rise.
- Turn the Prisma Dual power switch to the ON position.
- Wait for the control menu to appear.
- On the side, locate the air gauge and the blue air release control.
- Push the blue control to the right to allow air into the system.
Test platen movement (foot pedal)
- Press the foot pedal.
- Confirm the platen shifts smoothly to the opposite side.
- Press the press buttons on both sides simultaneously.
- Confirm the press function operates correctly.
Finish
- If all tests are successful, the Prisma Dual is fully unboxed and set up.