DESCRIPTION This guide walks through replacing the capping station pump and verifying proper installation.
- Open the printer cover.
- Release the printer carriage.
- Move the carriage away from the capping station to create working space.
- Using a screwdriver, remove the five screws securing the capping station cover.
- Remove the capping station cover.
- Locate the cable tie securing the pump cable.
- Use scissors to cut the cable tie.
- Identify the cable corresponding to the pump being replaced.
- Disconnect the pump cable.
- Open the right-side door of the printer.
- Locate the pump that corresponds to the disconnected cable.
- Remove the two mounting screws holding the pump in place.
- Pull the pump out.
- Disconnect the ink tube by twisting to unlock.
- Pull the cable fully out of the printer.
- Take the new pump.
- Connect the ink tubes to the pump.
- Twist to the right to fully tighten the tube connections.
- Feed the pump cable all the way through the printer.
- Insert the pump into its mounting slot.
- Secure the pump using the two mounting screws.
- Connect the pump cable.
- Use a zip tie to secure the cable neatly and keep it out of the way.
- Reinstall the capping station cover.
- Secure the cover using the five screws removed earlier.
- Turn the printer ON.
- Perform a head cleaning. VERIFICATION CHECK
- If ink flows through the lines during cleaning:
- The pump has been installed correctly.
- If ink does not flow:
- Recheck tube connections, cable connection, and pump seating.